 "version": "0.2",
 "seed": 20261116,
 "count": 220,
 "repeats": [
  "two_bus-01",
  "two_bus-02",
  "two_bus-03",
  "fault_with_cable-01",
  "fault_with_cable-02",
  "fault_with_cable-03",
  "idmt_grading-01",
  "idmt_grading-02",
  "idmt_grading-03",
  "earth_fault-01",
  "earth_fault-02",
  "earth_fault-03",
  "parallel_unequal-01",
  "parallel_unequal-02",
  "parallel_unequal-03"
 ],
 "questions": [
  {
   "id": "per_unit-01",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 40 MVA with an impedance of 10% on its own rating, at a rated voltage of 132 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 132 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.25,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.1 × (100/40) × (132/132)² = 0.25000 pu"
  },
  {
   "id": "per_unit-02",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 60 MVA with an impedance of 11.5% on its own rating, at a rated voltage of 220 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 209.0 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.212373,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.115 × (100/60) × (220/209.0)² = 0.21237 pu"
  },
  {
   "id": "per_unit-03",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 60 MVA with an impedance of 16% on its own rating, at a rated voltage of 220 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 220 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.266667,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.16 × (100/60) × (220/220)² = 0.26667 pu"
  },
  {
   "id": "per_unit-04",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 120 MVA with an impedance of 14% on its own rating, at a rated voltage of 132 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 132 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.116667,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.14 × (100/120) × (132/132)² = 0.11667 pu"
  },
  {
   "id": "per_unit-05",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 60 MVA with an impedance of 12% on its own rating, at a rated voltage of 330 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 313.5 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.221607,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.12 × (100/60) × (330/313.5)² = 0.22161 pu"
  },
  {
   "id": "per_unit-06",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 40 MVA with an impedance of 12% on its own rating, at a rated voltage of 220 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 231.0 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.272109,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.12 × (100/40) × (220/231.0)² = 0.27211 pu"
  },
  {
   "id": "per_unit-07",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 120 MVA with an impedance of 11.5% on its own rating, at a rated voltage of 132 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 132 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.0958333,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.115 × (100/120) × (132/132)² = 0.09583 pu"
  },
  {
   "id": "per_unit-08",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 160 MVA with an impedance of 14% on its own rating, at a rated voltage of 132 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 132 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.0875,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.14 × (100/160) × (132/132)² = 0.08750 pu"
  },
  {
   "id": "per_unit-09",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 40 MVA with an impedance of 10% on its own rating, at a rated voltage of 220 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 220 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.25,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.1 × (100/40) × (220/220)² = 0.25000 pu"
  },
  {
   "id": "per_unit-10",
   "topic": "Per-unit conversion",
   "level": "basic",
   "question": "A transformer is rated 40 MVA with an impedance of 16% on its own rating, at a rated voltage of 220 kV on the side considered. Express its impedance in per unit on a system base of 100 MVA and 209.0 kV.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.443213,
   "unit": "pu",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "z_new = z_old × (S_new/S_old) × (V_old/V_new)² = 0.16 × (100/40) × (220/209.0)² = 0.44321 pu"
  },
  {
   "id": "three_phase_power-01",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 132 kV (line to line) carries a balanced three-phase current of 420 A at a power factor of 0.97 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 93.1441,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 132 kV × 420 A × 0.97 = 93.1441 MW"
  },
  {
   "id": "three_phase_power-02",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 11 kV (line to line) carries a balanced three-phase current of 1600 A at a power factor of 0.9 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 27.4357,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 11 kV × 1600 A × 0.9 = 27.4357 MW"
  },
  {
   "id": "three_phase_power-03",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 11 kV (line to line) carries a balanced three-phase current of 1250 A at a power factor of 0.97 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 23.1012,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 11 kV × 1250 A × 0.97 = 23.1012 MW"
  },
  {
   "id": "three_phase_power-04",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 33 kV (line to line) carries a balanced three-phase current of 420 A at a power factor of 0.95 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 22.8059,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 33 kV × 420 A × 0.95 = 22.8059 MW"
  },
  {
   "id": "three_phase_power-05",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 132 kV (line to line) carries a balanced three-phase current of 640 A at a power factor of 0.9 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 131.691,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 132 kV × 640 A × 0.9 = 131.6913 MW"
  },
  {
   "id": "three_phase_power-06",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 33 kV (line to line) carries a balanced three-phase current of 420 A at a power factor of 0.9 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 21.6056,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 33 kV × 420 A × 0.9 = 21.6056 MW"
  },
  {
   "id": "three_phase_power-07",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 22 kV (line to line) carries a balanced three-phase current of 1250 A at a power factor of 0.95 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 45.2498,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 22 kV × 1250 A × 0.95 = 45.2498 MW"
  },
  {
   "id": "three_phase_power-08",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 33 kV (line to line) carries a balanced three-phase current of 250 A at a power factor of 0.98 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 14.0036,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 33 kV × 250 A × 0.98 = 14.0036 MW"
  },
  {
   "id": "three_phase_power-09",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 66 kV (line to line) carries a balanced three-phase current of 1600 A at a power factor of 0.92 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 168.272,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 66 kV × 1600 A × 0.92 = 168.2722 MW"
  },
  {
   "id": "three_phase_power-10",
   "topic": "Three-phase power",
   "level": "basic",
   "question": "A data-centre feeder at 33 kV (line to line) carries a balanced three-phase current of 180 A at a power factor of 0.95 lagging. What real power does it deliver?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 9.77396,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "P = √3 × V_LL × I × pf = √3 × 33 kV × 180 A × 0.95 = 9.7740 MW"
  },
  {
   "id": "pf_correction-01",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 20 MW at 0.85 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.97 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 7.38241,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.85) − tan(acos 0.97)) = 20 × (0.61974 − 0.25062) = 7.3824 Mvar"
  },
  {
   "id": "pf_correction-02",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 60 MW at 0.88 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.95 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 12.6635,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.88) − tan(acos 0.95)) = 60 × (0.53974 − 0.32868) = 12.6635 Mvar"
  },
  {
   "id": "pf_correction-03",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 120 MW at 0.85 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.98 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 50.0023,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.85) − tan(acos 0.98)) = 120 × (0.61974 − 0.20306) = 50.0023 Mvar"
  },
  {
   "id": "pf_correction-04",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 85 MW at 0.82 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.95 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 31.3922,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.82) − tan(acos 0.95)) = 85 × (0.69800 − 0.32868) = 31.3922 Mvar"
  },
  {
   "id": "pf_correction-05",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 60 MW at 0.85 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.99 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 28.6351,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.85) − tan(acos 0.99)) = 60 × (0.61974 − 0.14249) = 28.6351 Mvar"
  },
  {
   "id": "pf_correction-06",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 85 MW at 0.8 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.98 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 46.49,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.8) − tan(acos 0.98)) = 85 × (0.75000 − 0.20306) = 46.4900 Mvar"
  },
  {
   "id": "pf_correction-07",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 48 MW at 0.88 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.95 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 10.1308,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.88) − tan(acos 0.95)) = 48 × (0.53974 − 0.32868) = 10.1308 Mvar"
  },
  {
   "id": "pf_correction-08",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 60 MW at 0.85 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.97 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 22.1472,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.85) − tan(acos 0.97)) = 60 × (0.61974 − 0.25062) = 22.1472 Mvar"
  },
  {
   "id": "pf_correction-09",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 35 MW at 0.88 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.95 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 7.38706,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.88) − tan(acos 0.95)) = 35 × (0.53974 − 0.32868) = 7.3871 Mvar"
  },
  {
   "id": "pf_correction-10",
   "topic": "Power-factor correction",
   "level": "basic",
   "question": "A site draws 60 MW at 0.8 power factor lagging. How much capacitive reactive power must be added to raise the power factor to 0.98 lagging, with the real power unchanged?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Mvar. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 32.8165,
   "unit": "Mvar",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Qc = P × (tan(acos 0.8) − tan(acos 0.98)) = 60 × (0.75000 − 0.20306) = 32.8165 Mvar"
  },
  {
   "id": "transformer_loading-01",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 100 MVA transformer supplies a data hall drawing 90 MW at 0.9 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 100.0,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 90 / 0.9 = 100.0000 MVA; loading = S / S_rated = 100.0000 / 100 = 100.000%"
  },
  {
   "id": "transformer_loading-02",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 40 MVA transformer supplies a data hall drawing 30 MW at 0.93 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 80.6452,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 30 / 0.93 = 32.2581 MVA; loading = S / S_rated = 32.2581 / 40 = 80.645%"
  },
  {
   "id": "transformer_loading-03",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 80 MVA transformer supplies a data hall drawing 75 MW at 0.93 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 100.806,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 75 / 0.93 = 80.6452 MVA; loading = S / S_rated = 80.6452 / 80 = 100.806%"
  },
  {
   "id": "transformer_loading-04",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 160 MVA transformer supplies a data hall drawing 68 MW at 0.9 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 47.2222,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 68 / 0.9 = 75.5556 MVA; loading = S / S_rated = 75.5556 / 160 = 47.222%"
  },
  {
   "id": "transformer_loading-05",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 60 MVA transformer supplies a data hall drawing 30 MW at 0.98 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 51.0204,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 30 / 0.98 = 30.6122 MVA; loading = S / S_rated = 30.6122 / 60 = 51.020%"
  },
  {
   "id": "transformer_loading-06",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 100 MVA transformer supplies a data hall drawing 52 MW at 0.93 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 55.914,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 52 / 0.93 = 55.9140 MVA; loading = S / S_rated = 55.9140 / 100 = 55.914%"
  },
  {
   "id": "transformer_loading-07",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 80 MVA transformer supplies a data hall drawing 45 MW at 0.95 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 59.2105,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 45 / 0.95 = 47.3684 MVA; loading = S / S_rated = 47.3684 / 80 = 59.211%"
  },
  {
   "id": "transformer_loading-08",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 60 MVA transformer supplies a data hall drawing 30 MW at 0.9 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 55.5556,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 30 / 0.9 = 33.3333 MVA; loading = S / S_rated = 33.3333 / 60 = 55.556%"
  },
  {
   "id": "transformer_loading-09",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 80 MVA transformer supplies a data hall drawing 45 MW at 0.98 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 57.398,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 45 / 0.98 = 45.9184 MVA; loading = S / S_rated = 45.9184 / 80 = 57.398%"
  },
  {
   "id": "transformer_loading-10",
   "topic": "Transformer loading",
   "level": "basic",
   "question": "A 100 MVA transformer supplies a data hall drawing 68 MW at 0.93 power factor. What is the transformer's loading as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 73.1183,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = P / pf = 68 / 0.93 = 73.1183 MVA; loading = S / S_rated = 73.1183 / 100 = 73.118%"
  },
  {
   "id": "n_minus_1-01",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 70 MW data centre at 0.97 power factor is supplied through 2 identical 80 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 90.2062,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 70/0.97 = 72.1649 MVA shared by 1 transformer(s): 72.1649 / (1 × 80) = 90.206%"
  },
  {
   "id": "n_minus_1-02",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 140 MW data centre at 0.95 power factor is supplied through 3 identical 100 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 73.6842,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 140/0.95 = 147.3684 MVA shared by 2 transformer(s): 147.3684 / (2 × 100) = 73.684%"
  },
  {
   "id": "n_minus_1-03",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 70 MW data centre at 0.95 power factor is supplied through 2 identical 120 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 61.4035,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 70/0.95 = 73.6842 MVA shared by 1 transformer(s): 73.6842 / (1 × 120) = 61.404%"
  },
  {
   "id": "n_minus_1-04",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 140 MW data centre at 0.93 power factor is supplied through 2 identical 150 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 100.358,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 140/0.93 = 150.5376 MVA shared by 1 transformer(s): 150.5376 / (1 × 150) = 100.358%"
  },
  {
   "id": "n_minus_1-05",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 90 MW data centre at 0.97 power factor is supplied through 3 identical 80 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 57.9897,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 90/0.97 = 92.7835 MVA shared by 2 transformer(s): 92.7835 / (2 × 80) = 57.990%"
  },
  {
   "id": "n_minus_1-06",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 90 MW data centre at 0.95 power factor is supplied through 2 identical 120 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 78.9474,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 90/0.95 = 94.7368 MVA shared by 1 transformer(s): 94.7368 / (1 × 120) = 78.947%"
  },
  {
   "id": "n_minus_1-07",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 110 MW data centre at 0.93 power factor is supplied through 2 identical 100 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 118.28,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 110/0.93 = 118.2796 MVA shared by 1 transformer(s): 118.2796 / (1 × 100) = 118.280%"
  },
  {
   "id": "n_minus_1-08",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 70 MW data centre at 0.93 power factor is supplied through 2 identical 150 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 50.1792,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 70/0.93 = 75.2688 MVA shared by 1 transformer(s): 75.2688 / (1 × 150) = 50.179%"
  },
  {
   "id": "n_minus_1-09",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 180 MW data centre at 0.95 power factor is supplied through 3 identical 100 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 94.7368,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 180/0.95 = 189.4737 MVA shared by 2 transformer(s): 189.4737 / (2 × 100) = 94.737%"
  },
  {
   "id": "n_minus_1-10",
   "topic": "N−1 transformer capacity",
   "level": "applied",
   "question": "A 90 MW data centre at 0.97 power factor is supplied through 2 identical 100 MVA transformers in parallel that share load equally. If one transformer is out of service, what is the loading of each remaining transformer as a percentage of its rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 92.7835,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "S = 90/0.97 = 92.7835 MVA shared by 1 transformer(s): 92.7835 / (1 × 100) = 92.784%"
  },
  {
   "id": "fault_current-01",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 4000 MVA. A 60 MVA transformer with 14% impedance (on its own rating) steps down to 66 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 66 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 3.38622,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/4000 = 0.02500 pu; Zt = 0.14 × 100/60 = 0.23333 pu; fault level = 100/(0.02500 + 0.23333) = 387.097 MVA; I = 387.097 / (√3 × 66) = 3.3862 kA"
  },
  {
   "id": "fault_current-02",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 1500 MVA. A 80 MVA transformer with 18% impedance (on its own rating) steps down to 22 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 22 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 8.99767,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/1500 = 0.06667 pu; Zt = 0.18 × 100/80 = 0.22500 pu; fault level = 100/(0.06667 + 0.22500) = 342.857 MVA; I = 342.857 / (√3 × 22) = 8.9977 kA"
  },
  {
   "id": "fault_current-03",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 1500 MVA. A 100 MVA transformer with 18% impedance (on its own rating) steps down to 22 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 22 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 10.6391,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/1500 = 0.06667 pu; Zt = 0.18 × 100/100 = 0.18000 pu; fault level = 100/(0.06667 + 0.18000) = 405.405 MVA; I = 405.405 / (√3 × 22) = 10.6391 kA"
  },
  {
   "id": "fault_current-04",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 8000 MVA. A 100 MVA transformer with 18% impedance (on its own rating) steps down to 66 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 66 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 4.54428,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/8000 = 0.01250 pu; Zt = 0.18 × 100/100 = 0.18000 pu; fault level = 100/(0.01250 + 0.18000) = 519.481 MVA; I = 519.481 / (√3 × 66) = 4.5443 kA"
  },
  {
   "id": "fault_current-05",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 8000 MVA. A 100 MVA transformer with 12% impedance (on its own rating) steps down to 22 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 22 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 19.8062,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/8000 = 0.01250 pu; Zt = 0.12 × 100/100 = 0.12000 pu; fault level = 100/(0.01250 + 0.12000) = 754.717 MVA; I = 754.717 / (√3 × 22) = 19.8062 kA"
  },
  {
   "id": "fault_current-06",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 4000 MVA. A 80 MVA transformer with 10% impedance (on its own rating) steps down to 33 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 33 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 11.6636,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/4000 = 0.02500 pu; Zt = 0.1 × 100/80 = 0.12500 pu; fault level = 100/(0.02500 + 0.12500) = 666.667 MVA; I = 666.667 / (√3 × 33) = 11.6636 kA"
  },
  {
   "id": "fault_current-07",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 2500 MVA. A 80 MVA transformer with 10% impedance (on its own rating) steps down to 33 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 33 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 10.6033,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/2500 = 0.04000 pu; Zt = 0.1 × 100/80 = 0.12500 pu; fault level = 100/(0.04000 + 0.12500) = 606.061 MVA; I = 606.061 / (√3 × 33) = 10.6033 kA"
  },
  {
   "id": "fault_current-08",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 8000 MVA. A 160 MVA transformer with 10% impedance (on its own rating) steps down to 66 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 66 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 11.6636,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/8000 = 0.01250 pu; Zt = 0.1 × 100/160 = 0.06250 pu; fault level = 100/(0.01250 + 0.06250) = 1333.333 MVA; I = 1333.333 / (√3 × 66) = 11.6636 kA"
  },
  {
   "id": "fault_current-09",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 8000 MVA. A 60 MVA transformer with 16% impedance (on its own rating) steps down to 22 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 22 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 9.40055,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/8000 = 0.01250 pu; Zt = 0.16 × 100/60 = 0.26667 pu; fault level = 100/(0.01250 + 0.26667) = 358.209 MVA; I = 358.209 / (√3 × 22) = 9.4005 kA"
  },
  {
   "id": "fault_current-10",
   "topic": "Fault current through a transformer",
   "level": "applied",
   "question": "The 132 kV busbar feeding a data-centre substation has a three-phase fault level of 2500 MVA. A 100 MVA transformer with 10% impedance (on its own rating) steps down to 33 kV. Neglect resistance, load current and any other source, and take the pre-fault voltage as 1.0 pu. What is the three-phase fault current at the 33 kV terminals of the transformer?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 12.4968,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "On 100 MVA: Zs = 100/2500 = 0.04000 pu; Zt = 0.1 × 100/100 = 0.10000 pu; fault level = 100/(0.04000 + 0.10000) = 714.286 MVA; I = 714.286 / (√3 × 33) = 12.4968 kA"
  },
  {
   "id": "scr-01",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 220 kV connection point the three-phase fault current is 20 kA. A 600 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 12.7017,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 220 × 20 = 7621.024 MVA; SCR = 7621.024 / 600 = 12.7017"
  },
  {
   "id": "scr-02",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 132 kV connection point the three-phase fault current is 31.5 kA. A 150 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 48.0124,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 132 × 31.5 = 7201.867 MVA; SCR = 7201.867 / 150 = 48.0124"
  },
  {
   "id": "scr-03",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 330 kV connection point the three-phase fault current is 8 kA. A 300 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 15.242,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 330 × 8 = 4572.614 MVA; SCR = 4572.614 / 300 = 15.2420"
  },
  {
   "id": "scr-04",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 330 kV connection point the three-phase fault current is 20 kA. A 150 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 76.2102,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 330 × 20 = 11431.535 MVA; SCR = 11431.535 / 150 = 76.2102"
  },
  {
   "id": "scr-05",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 132 kV connection point the three-phase fault current is 25 kA. A 900 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 6.35085,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 132 × 25 = 5715.768 MVA; SCR = 5715.768 / 900 = 6.3509"
  },
  {
   "id": "scr-06",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 220 kV connection point the three-phase fault current is 12.5 kA. A 450 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 10.5848,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 220 × 12.5 = 4763.140 MVA; SCR = 4763.140 / 450 = 10.5848"
  },
  {
   "id": "scr-07",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 132 kV connection point the three-phase fault current is 12.5 kA. A 150 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 19.0526,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 132 × 12.5 = 2857.884 MVA; SCR = 2857.884 / 150 = 19.0526"
  },
  {
   "id": "scr-08",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 220 kV connection point the three-phase fault current is 16 kA. A 900 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 6.77424,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 220 × 16 = 6096.819 MVA; SCR = 6096.819 / 900 = 6.7742"
  },
  {
   "id": "scr-09",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 132 kV connection point the three-phase fault current is 8 kA. A 450 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 4.06455,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 132 × 8 = 1829.046 MVA; SCR = 1829.046 / 450 = 4.0645"
  },
  {
   "id": "scr-10",
   "topic": "Short-circuit ratio",
   "level": "basic",
   "question": "At a 220 kV connection point the three-phase fault current is 25 kA. A 300 MW load is proposed there. What is the short-circuit ratio (three-phase fault level divided by the load's rated power)?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain ratio (no unit). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 31.7543,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Fault level = √3 × 220 × 25 = 9526.279 MVA; SCR = 9526.279 / 300 = 31.7543"
  },
  {
   "id": "voltage_drop-01",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 5 km three-phase 33 kV feeder has R = 0.16 Ω/km and X = 0.12 Ω/km per phase. It supplies 8 MW at 0.9 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 33 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.80117,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.9) = 3.8746 Mvar; R = 0.800 Ω, X = 0.600 Ω; ΔV = (0.800×8 + 0.600×3.8746) / 33² = 0.008012 pu = 0.8012%"
  },
  {
   "id": "voltage_drop-02",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 5 km three-phase 22 kV feeder has R = 0.1 Ω/km and X = 0.32 Ω/km per phase. It supplies 6 MW at 0.95 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 22 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.27177,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.95) = 1.9721 Mvar; R = 0.500 Ω, X = 1.600 Ω; ΔV = (0.500×6 + 1.600×1.9721) / 22² = 0.012718 pu = 1.2718%"
  },
  {
   "id": "voltage_drop-03",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 12 km three-phase 33 kV feeder has R = 0.2 Ω/km and X = 0.35 Ω/km per phase. It supplies 15 MW at 0.98 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 33 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 4.4805,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.98) = 3.0459 Mvar; R = 2.400 Ω, X = 4.200 Ω; ΔV = (2.400×15 + 4.200×3.0459) / 33² = 0.044805 pu = 4.4805%"
  },
  {
   "id": "voltage_drop-04",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 12 km three-phase 22 kV feeder has R = 0.2 Ω/km and X = 0.35 Ω/km per phase. It supplies 6 MW at 0.9 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 22 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 5.49688,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.9) = 2.9059 Mvar; R = 2.400 Ω, X = 4.200 Ω; ΔV = (2.400×6 + 4.200×2.9059) / 22² = 0.054969 pu = 5.4969%"
  },
  {
   "id": "voltage_drop-05",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 12 km three-phase 22 kV feeder has R = 0.2 Ω/km and X = 0.35 Ω/km per phase. It supplies 4 MW at 0.98 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 22 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.6883,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.98) = 0.8122 Mvar; R = 2.400 Ω, X = 4.200 Ω; ΔV = (2.400×4 + 4.200×0.8122) / 22² = 0.026883 pu = 2.6883%"
  },
  {
   "id": "voltage_drop-06",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 8 km three-phase 33 kV feeder has R = 0.16 Ω/km and X = 0.12 Ω/km per phase. It supplies 6 MW at 0.9 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 33 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.961405,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.9) = 2.9059 Mvar; R = 1.280 Ω, X = 0.960 Ω; ΔV = (1.280×6 + 0.960×2.9059) / 33² = 0.009614 pu = 0.9614%"
  },
  {
   "id": "voltage_drop-07",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 5 km three-phase 11 kV feeder has R = 0.2 Ω/km and X = 0.35 Ω/km per phase. It supplies 4 MW at 0.95 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 11 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 5.20726,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.95) = 1.3147 Mvar; R = 1.000 Ω, X = 1.750 Ω; ΔV = (1.000×4 + 1.750×1.3147) / 11² = 0.052073 pu = 5.2073%"
  },
  {
   "id": "voltage_drop-08",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 12 km three-phase 33 kV feeder has R = 0.16 Ω/km and X = 0.12 Ω/km per phase. It supplies 10 MW at 0.9 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 33 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.40351,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.9) = 4.8432 Mvar; R = 1.920 Ω, X = 1.440 Ω; ΔV = (1.920×10 + 1.440×4.8432) / 33² = 0.024035 pu = 2.4035%"
  },
  {
   "id": "voltage_drop-09",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 5 km three-phase 33 kV feeder has R = 0.2 Ω/km and X = 0.35 Ω/km per phase. It supplies 6 MW at 0.98 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 33 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.746751,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.98) = 1.2184 Mvar; R = 1.000 Ω, X = 1.750 Ω; ΔV = (1.000×6 + 1.750×1.2184) / 33² = 0.007468 pu = 0.7468%"
  },
  {
   "id": "voltage_drop-10",
   "topic": "Feeder voltage drop",
   "level": "applied",
   "question": "A 15 km three-phase 33 kV feeder has R = 0.1 Ω/km and X = 0.32 Ω/km per phase. It supplies 15 MW at 0.95 power factor lagging at its far end. Using the approximation ΔV ≈ (R·P + X·Q) / V², what is the voltage drop along the feeder as a percentage of 33 kV?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 4.23923,
   "unit": "%",
   "tolerance": {
    "relative": 0.02
   },
   "solution": "Q = P tan(acos 0.95) = 4.9303 Mvar; R = 1.500 Ω, X = 4.800 Ω; ΔV = (1.500×15 + 4.800×4.9303) / 33² = 0.042392 pu = 4.2392%"
  },
  {
   "id": "two_bus-01",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.005 + j0.1 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 120 MW at power factor 0.98 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.960719,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 1.2 pu, Q = 0.24367 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.939266, c = 0.01503124: V2 = 0.96072 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-02",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.02 + j0.1 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 150 MW at power factor 0.98 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.922189,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 1.5 pu, Q = 0.30459 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.879082, c = 0.02436485: V2 = 0.92219 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-03",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.03 + j0.1 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 150 MW at power factor 0.98 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.904356,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 1.5 pu, Q = 0.30459 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.849082, c = 0.02553623: V2 = 0.90436 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-04",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.03 + j0.08 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 80 MW at power factor 0.95 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.950896,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 0.8 pu, Q = 0.26295 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.909928, c = 0.00517673: V2 = 0.95090 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-05",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.005 + j0.1 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 120 MW at power factor 0.95 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.944016,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 1.2 pu, Q = 0.39442 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.909116, c = 0.01599557: V2 = 0.94402 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-06",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.02 + j0.08 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 120 MW at power factor 0.95 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.936223,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 1.2 pu, Q = 0.39442 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.888893, c = 0.01084986: V2 = 0.93622 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-07",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.02 + j0.05 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 80 MW at power factor 1.0. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.982893,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 0.8 pu, Q = 0.00000 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.968000, c = 0.00185600: V2 = 0.98289 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-08",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.02 + j0.08 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 200 MW at power factor 0.98 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.905817,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 2.0 pu, Q = 0.40612 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.855021, c = 0.02832153: V2 = 0.90582 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-09",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.02 + j0.05 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 120 MW at power factor 1.0. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.973444,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 1.2 pu, Q = 0.00000 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.952000, c = 0.00417600: V2 = 0.97344 pu (the high-voltage root)."
  },
  {
   "id": "two_bus-10",
   "topic": "Exact two-bus power flow",
   "level": "analysis",
   "question": "Bus 1 is an infinite bus held at 1.0 pu. It feeds bus 2 through a line of impedance 0.02 + j0.05 pu (100 MVA base; neglect shunt admittance). Bus 2 supplies a data-centre load of 250 MW at power factor 0.98 lagging. Solving the power-flow equations exactly (not with a linear approximation), what is the voltage magnitude at bus 2? Give it to four decimal places.\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in per unit. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.909065,
   "unit": "pu",
   "tolerance": {
    "absolute": 0.0015
   },
   "solution": "P = 2.5 pu, Q = 0.50765 pu. With V1 = 1: V2⁴ + (2(RP+XQ) − 1)V2² + (R²+X²)(P²+Q²) = 0, so V2² = (−b + √(b²−4c))/2 with b = -0.849235, c = 0.01887234: V2 = 0.90906 pu (the high-voltage root)."
  },
  {
   "id": "peak_current-01",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 12 kA and the network X/R ratio at the fault is 8. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 28.7404,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/8) = 1.69354; ip = κ·√2·I\"k = 1.69354 × √2 × 12 = 28.7404 kA"
  },
  {
   "id": "peak_current-02",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 40 kA and the network X/R ratio at the fault is 30. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 107.862,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/30) = 1.90674; ip = κ·√2·I\"k = 1.90674 × √2 × 40 = 107.8615 kA"
  },
  {
   "id": "peak_current-03",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 12 kA and the network X/R ratio at the fault is 10. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 29.6306,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/10) = 1.74600; ip = κ·√2·I\"k = 1.74600 × √2 × 12 = 29.6306 kA"
  },
  {
   "id": "peak_current-04",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 25 kA and the network X/R ratio at the fault is 30. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 67.4135,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/30) = 1.90674; ip = κ·√2·I\"k = 1.90674 × √2 × 25 = 67.4135 kA"
  },
  {
   "id": "peak_current-05",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 12 kA and the network X/R ratio at the fault is 20. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 31.6245,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/20) = 1.86349; ip = κ·√2·I\"k = 1.86349 × √2 × 12 = 31.6245 kA"
  },
  {
   "id": "peak_current-06",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 16 kA and the network X/R ratio at the fault is 5. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 35.2498,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/5) = 1.55784; ip = κ·√2·I\"k = 1.55784 × √2 × 16 = 35.2498 kA"
  },
  {
   "id": "peak_current-07",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 20 kA and the network X/R ratio at the fault is 30. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 53.9308,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/30) = 1.90674; ip = κ·√2·I\"k = 1.90674 × √2 × 20 = 53.9308 kA"
  },
  {
   "id": "peak_current-08",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 16 kA and the network X/R ratio at the fault is 10. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 39.5075,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/10) = 1.74600; ip = κ·√2·I\"k = 1.74600 × √2 × 16 = 39.5075 kA"
  },
  {
   "id": "peak_current-09",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 25 kA and the network X/R ratio at the fault is 5. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 55.0778,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/5) = 1.55784; ip = κ·√2·I\"k = 1.55784 × √2 × 25 = 55.0778 kA"
  },
  {
   "id": "peak_current-10",
   "topic": "Peak short-circuit current (IEC 60909)",
   "level": "applied",
   "question": "At a substation busbar the initial symmetrical three-phase short-circuit current I\"k is 12 kA and the network X/R ratio at the fault is 14. Using the IEC 60909 factor κ = 1.02 + 0.98·e^(−3R/X), what is the peak short-circuit current ip?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 30.7333,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "κ = 1.02 + 0.98·e^(−3/14) = 1.81098; ip = κ·√2·I\"k = 1.81098 × √2 × 12 = 30.7333 kA"
  },
  {
   "id": "rocof-01",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 80,000 MW·s of synchronous inertia (stored kinetic energy). A 500 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.15625,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 500 × 50 / (2 × 80000) = 0.15625 Hz/s"
  },
  {
   "id": "rocof-02",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 40,000 MW·s of synchronous inertia (stored kinetic energy). A 500 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.3125,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 500 × 50 / (2 × 40000) = 0.31250 Hz/s"
  },
  {
   "id": "rocof-03",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 120,000 MW·s of synchronous inertia (stored kinetic energy). A 300 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.0625,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 300 × 50 / (2 × 120000) = 0.06250 Hz/s"
  },
  {
   "id": "rocof-04",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 120,000 MW·s of synchronous inertia (stored kinetic energy). A 750 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.15625,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 750 × 50 / (2 × 120000) = 0.15625 Hz/s"
  },
  {
   "id": "rocof-05",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 60,000 MW·s of synchronous inertia (stored kinetic energy). A 500 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.208333,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 500 × 50 / (2 × 60000) = 0.20833 Hz/s"
  },
  {
   "id": "rocof-06",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 40,000 MW·s of synchronous inertia (stored kinetic energy). A 1500 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.9375,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 1500 × 50 / (2 × 40000) = 0.93750 Hz/s"
  },
  {
   "id": "rocof-07",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 60,000 MW·s of synchronous inertia (stored kinetic energy). A 1000 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.416667,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 1000 × 50 / (2 × 60000) = 0.41667 Hz/s"
  },
  {
   "id": "rocof-08",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 120,000 MW·s of synchronous inertia (stored kinetic energy). A 1500 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.3125,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 1500 × 50 / (2 × 120000) = 0.31250 Hz/s"
  },
  {
   "id": "rocof-09",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 60,000 MW·s of synchronous inertia (stored kinetic energy). A 300 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.125,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 300 × 50 / (2 × 60000) = 0.12500 Hz/s"
  },
  {
   "id": "rocof-10",
   "topic": "Rate of change of frequency",
   "level": "applied",
   "question": "A 50 Hz power system has 40,000 MW·s of synchronous inertia (stored kinetic energy). A 750 MW data-centre load trips off suddenly. Ignoring load damping and any control response, what is the initial rate of change of frequency, as a magnitude?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz/s. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.46875,
   "unit": "Hz/s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "RoCoF = ΔP·f0 / (2·E) = 750 × 50 / (2 × 40000) = 0.46875 Hz/s"
  },
  {
   "id": "droop-01",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 200 MW generator has a 4% speed droop on a 50 Hz system. The frequency falls by 0.2 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 20.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.2/50) / 0.04 × 200 = 20.0000 MW"
  },
  {
   "id": "droop-02",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 660 MW generator has a 5% speed droop on a 50 Hz system. The frequency falls by 0.3 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 79.2,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.3/50) / 0.05 × 660 = 79.2000 MW"
  },
  {
   "id": "droop-03",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 660 MW generator has a 3% speed droop on a 50 Hz system. The frequency falls by 0.1 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 44.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.1/50) / 0.03 × 660 = 44.0000 MW"
  },
  {
   "id": "droop-04",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 300 MW generator has a 5% speed droop on a 50 Hz system. The frequency falls by 0.3 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 36.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.3/50) / 0.05 × 300 = 36.0000 MW"
  },
  {
   "id": "droop-05",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 450 MW generator has a 4% speed droop on a 50 Hz system. The frequency falls by 0.2 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 45.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.2/50) / 0.04 × 450 = 45.0000 MW"
  },
  {
   "id": "droop-06",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 200 MW generator has a 5% speed droop on a 50 Hz system. The frequency falls by 0.1 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 8.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.1/50) / 0.05 × 200 = 8.0000 MW"
  },
  {
   "id": "droop-07",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 200 MW generator has a 5% speed droop on a 50 Hz system. The frequency falls by 0.2 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 16.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.2/50) / 0.05 × 200 = 16.0000 MW"
  },
  {
   "id": "droop-08",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 200 MW generator has a 3% speed droop on a 50 Hz system. The frequency falls by 0.2 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 26.6667,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.2/50) / 0.03 × 200 = 26.6667 MW"
  },
  {
   "id": "droop-09",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 660 MW generator has a 3% speed droop on a 50 Hz system. The frequency falls by 0.25 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 110.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.25/50) / 0.03 × 660 = 110.0000 MW"
  },
  {
   "id": "droop-10",
   "topic": "Governor droop response",
   "level": "basic",
   "question": "A 660 MW generator has a 5% speed droop on a 50 Hz system. The frequency falls by 0.2 Hz and stays there. Ignoring deadband and headroom limits, by how much does the generator's output rise?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 52.8,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔP = (Δf/f0) / R × Pn = (0.2/50) / 0.05 × 660 = 52.8000 MW"
  },
  {
   "id": "ups_energy-01",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 4 MW IT load for 5 minutes. The inverter is 96% efficient and only 80% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.434028,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 4 × 5/60 / (0.96 × 0.8) = 0.43403 MWh"
  },
  {
   "id": "ups_energy-02",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 4 MW IT load for 10 minutes. The inverter is 95% efficient and only 85% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.825593,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 4 × 10/60 / (0.95 × 0.85) = 0.82559 MWh"
  },
  {
   "id": "ups_energy-03",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 10 MW IT load for 15 minutes. The inverter is 97% efficient and only 90% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.86369,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 10 × 15/60 / (0.97 × 0.9) = 2.86369 MWh"
  },
  {
   "id": "ups_energy-04",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 10 MW IT load for 10 minutes. The inverter is 97% efficient and only 90% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.90913,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 10 × 10/60 / (0.97 × 0.9) = 1.90913 MWh"
  },
  {
   "id": "ups_energy-05",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 6 MW IT load for 10 minutes. The inverter is 95% efficient and only 90% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.16959,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 6 × 10/60 / (0.95 × 0.9) = 1.16959 MWh"
  },
  {
   "id": "ups_energy-06",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 2 MW IT load for 5 minutes. The inverter is 95% efficient and only 85% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.206398,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 2 × 5/60 / (0.95 × 0.85) = 0.20640 MWh"
  },
  {
   "id": "ups_energy-07",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 2 MW IT load for 15 minutes. The inverter is 96% efficient and only 85% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.612745,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 2 × 15/60 / (0.96 × 0.85) = 0.61275 MWh"
  },
  {
   "id": "ups_energy-08",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 2 MW IT load for 5 minutes. The inverter is 97% efficient and only 80% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.214777,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 2 × 5/60 / (0.97 × 0.8) = 0.21478 MWh"
  },
  {
   "id": "ups_energy-09",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 6 MW IT load for 5 minutes. The inverter is 96% efficient and only 80% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.651042,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 6 × 5/60 / (0.96 × 0.8) = 0.65104 MWh"
  },
  {
   "id": "ups_energy-10",
   "topic": "UPS battery energy",
   "level": "basic",
   "question": "A UPS must carry a 4 MW IT load for 15 minutes. The inverter is 96% efficient and only 90% of the battery's nameplate energy may be used. What nameplate battery energy is needed?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MWh. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.15741,
   "unit": "MWh",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "E = P·t / (η·DoD) = 4 × 15/60 / (0.96 × 0.9) = 1.15741 MWh"
  },
  {
   "id": "thd-01",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 800 A and harmonic components 5th 240 A, 7th 96 A, 11th 48 A, 13th 24 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 33.0,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(240² + 96² + 48² + 24²) / 800 = 33.0000%"
  },
  {
   "id": "thd-02",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 400 A and harmonic components 5th 88 A, 7th 48 A, 11th 16 A, 13th 16 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 25.6905,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(88² + 48² + 16² + 16²) / 400 = 25.6905%"
  },
  {
   "id": "thd-03",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 1000 A and harmonic components 5th 220 A, 7th 90 A, 11th 80 A, 13th 40 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 25.3969,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(220² + 90² + 80² + 40²) / 1000 = 25.3969%"
  },
  {
   "id": "thd-04",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 800 A and harmonic components 5th 240 A, 7th 96 A, 11th 64 A, 13th 40 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 33.6601,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(240² + 96² + 64² + 40²) / 800 = 33.6601%"
  },
  {
   "id": "thd-05",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 800 A and harmonic components 5th 144 A, 7th 96 A, 11th 48 A, 13th 32 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 22.8035,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(144² + 96² + 48² + 32²) / 800 = 22.8035%"
  },
  {
   "id": "thd-06",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 800 A and harmonic components 5th 240 A, 7th 48 A, 11th 64 A, 13th 40 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 32.0156,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(240² + 48² + 64² + 40²) / 800 = 32.0156%"
  },
  {
   "id": "thd-07",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 600 A and harmonic components 5th 132 A, 7th 54 A, 11th 48 A, 13th 30 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 25.5734,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(132² + 54² + 48² + 30²) / 600 = 25.5734%"
  },
  {
   "id": "thd-08",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 1000 A and harmonic components 5th 300 A, 7th 90 A, 11th 40 A, 13th 30 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 31.7175,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(300² + 90² + 40² + 30²) / 1000 = 31.7175%"
  },
  {
   "id": "thd-09",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 600 A and harmonic components 5th 72 A, 7th 36 A, 11th 24 A, 13th 18 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 14.3178,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(72² + 36² + 24² + 18²) / 600 = 14.3178%"
  },
  {
   "id": "thd-10",
   "topic": "Harmonic distortion",
   "level": "basic",
   "question": "The phase current of a data hall's supply has a fundamental component of 1000 A and harmonic components 5th 180 A, 7th 90 A, 11th 80 A, 13th 30 A (all other harmonics negligible). What is the current total harmonic distortion (THD), relative to the fundamental?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 21.8632,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "THD = √(Σ Ih²) / I1 = √(180² + 90² + 80² + 30²) / 1000 = 21.8632%"
  },
  {
   "id": "capacitor_step-01",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 5 Mvar capacitor bank is switched in at a 33 kV data-centre busbar whose three-phase fault level is 600 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.833333,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 5 / 600 = 0.00833 pu = 0.8333%"
  },
  {
   "id": "capacitor_step-02",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 8 Mvar capacitor bank is switched in at a 11 kV data-centre busbar whose three-phase fault level is 600 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.33333,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 8 / 600 = 0.01333 pu = 1.3333%"
  },
  {
   "id": "capacitor_step-03",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 10 Mvar capacitor bank is switched in at a 22 kV data-centre busbar whose three-phase fault level is 1200 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.833333,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 10 / 1200 = 0.00833 pu = 0.8333%"
  },
  {
   "id": "capacitor_step-04",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 20 Mvar capacitor bank is switched in at a 11 kV data-centre busbar whose three-phase fault level is 900 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.22222,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 20 / 900 = 0.02222 pu = 2.2222%"
  },
  {
   "id": "capacitor_step-05",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 15 Mvar capacitor bank is switched in at a 33 kV data-centre busbar whose three-phase fault level is 600 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.5,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 15 / 600 = 0.02500 pu = 2.5000%"
  },
  {
   "id": "capacitor_step-06",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 10 Mvar capacitor bank is switched in at a 33 kV data-centre busbar whose three-phase fault level is 900 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.11111,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 10 / 900 = 0.01111 pu = 1.1111%"
  },
  {
   "id": "capacitor_step-07",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 10 Mvar capacitor bank is switched in at a 22 kV data-centre busbar whose three-phase fault level is 600 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.66667,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 10 / 600 = 0.01667 pu = 1.6667%"
  },
  {
   "id": "capacitor_step-08",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 5 Mvar capacitor bank is switched in at a 33 kV data-centre busbar whose three-phase fault level is 1200 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.416667,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 5 / 1200 = 0.00417 pu = 0.4167%"
  },
  {
   "id": "capacitor_step-09",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 15 Mvar capacitor bank is switched in at a 11 kV data-centre busbar whose three-phase fault level is 400 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 3.75,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 15 / 400 = 0.03750 pu = 3.7500%"
  },
  {
   "id": "capacitor_step-10",
   "topic": "Capacitor switching voltage step",
   "level": "basic",
   "question": "A 20 Mvar capacitor bank is switched in at a 11 kV data-centre busbar whose three-phase fault level is 250 MVA. Using ΔV ≈ Q / S_sc, what is the resulting steady-state voltage rise as a percentage?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 8.0,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "ΔV ≈ Qc / S_sc = 20 / 250 = 0.08000 pu = 8.0000%"
  },
  {
   "id": "earth_fault-01",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 22 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.3 pu and Z0 = j0.3 pu on a 100 MVA, 22 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is solidly earthed. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 8.74773,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 22²/100 = 4.8400 Ω; Zn = 0.00000+j0.00000 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j0.90000| = 3.33333 pu; I_base = 100/(√3×22) = 2.62432 kA; I_f = 8.7477 kA"
  },
  {
   "id": "earth_fault-02",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 11 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.2 pu and Z0 = j0.1 pu on a 100 MVA, 11 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 5 Ω resistor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.26914,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 11²/100 = 1.2100 Ω; Zn = 4.13223+j0.00000 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|12.39669+j0.50000| = 0.24180 pu; I_base = 100/(√3×11) = 5.24864 kA; I_f = 1.2691 kA"
  },
  {
   "id": "earth_fault-03",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 11 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.4 pu and Z0 = j0.2 pu on a 100 MVA, 11 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is solidly earthed. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 15.7459,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 11²/100 = 1.2100 Ω; Zn = 0.00000+j0.00000 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j1.00000| = 3.00000 pu; I_base = 100/(√3×11) = 5.24864 kA; I_f = 15.7459 kA"
  },
  {
   "id": "earth_fault-04",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 22 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.4 pu and Z0 = j0.15 pu on a 100 MVA, 22 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 20 Ω resistor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.633229,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 22²/100 = 4.8400 Ω; Zn = 4.13223+j0.00000 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|12.39669+j0.95000| = 0.24129 pu; I_base = 100/(√3×22) = 2.62432 kA; I_f = 0.6332 kA"
  },
  {
   "id": "earth_fault-05",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 11 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.15 pu and Z0 = j0.1 pu on a 100 MVA, 11 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 2 Ω reactor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.9384,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 11²/100 = 1.2100 Ω; Zn = 0.00000+j1.65289 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j5.35868| = 0.55984 pu; I_base = 100/(√3×11) = 5.24864 kA; I_f = 2.9384 kA"
  },
  {
   "id": "earth_fault-06",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 11 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.3 pu and Z0 = j0.1 pu on a 100 MVA, 11 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 2 Ω reactor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.78261,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 11²/100 = 1.2100 Ω; Zn = 0.00000+j1.65289 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j5.65868| = 0.53016 pu; I_base = 100/(√3×11) = 5.24864 kA; I_f = 2.7826 kA"
  },
  {
   "id": "earth_fault-07",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 22 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.25 pu and Z0 = j0.1 pu on a 100 MVA, 22 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 5 Ω resistor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.49403,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 22²/100 = 4.8400 Ω; Zn = 1.03306+j0.00000 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|3.09917+j0.60000| = 0.95035 pu; I_base = 100/(√3×22) = 2.62432 kA; I_f = 2.4940 kA"
  },
  {
   "id": "earth_fault-08",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 11 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.4 pu and Z0 = j0.2 pu on a 100 MVA, 11 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 2 Ω reactor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 2.64252,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 11²/100 = 1.2100 Ω; Zn = 0.00000+j1.65289 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j5.95868| = 0.50347 pu; I_base = 100/(√3×11) = 5.24864 kA; I_f = 2.6425 kA"
  },
  {
   "id": "earth_fault-09",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 22 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.25 pu and Z0 = j0.2 pu on a 100 MVA, 22 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is solidly earthed. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 11.2471,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 22²/100 = 4.8400 Ω; Zn = 0.00000+j0.00000 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j0.70000| = 4.28571 pu; I_base = 100/(√3×22) = 2.62432 kA; I_f = 11.2471 kA"
  },
  {
   "id": "earth_fault-10",
   "topic": "Earth-fault current from sequence impedances",
   "level": "analysis",
   "question": "At a 33 kV busbar the Thévenin sequence impedances seen from the fault are Z1 = Z2 = j0.2 pu and Z0 = j0.2 pu on a 100 MVA, 33 kV base, where Z0 does not yet include the neutral earthing. The supply transformer's star point is earthed through a 10 Ω reactor. Neglect all other resistance and take the pre-fault voltage as 1.0 pu. What is the current in a single-line-to-earth fault at the busbar?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 1.56451,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Z_base = 33²/100 = 10.8900 Ω; Zn = 0.00000+j0.91827 pu; I_f = 3/|Z1+Z2+Z0+3Zn| = 3/|0.00000+j3.35482| = 0.89424 pu; I_base = 100/(√3×33) = 1.74955 kA; I_f = 1.5645 kA"
  },
  {
   "id": "idmt_time-01",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 500 A primary and its TMS is 0.3. How long does it take to operate for a fault current of 6.5 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.797909,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 6500/500 = 13.0000; t = 0.3 × 0.14 / (13.0000^0.02 − 1) = 0.7979 s"
  },
  {
   "id": "idmt_time-02",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 500 A primary and its TMS is 0.1. How long does it take to operate for a fault current of 4 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.329677,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 4000/500 = 8.0000; t = 0.1 × 0.14 / (8.0000^0.02 − 1) = 0.3297 s"
  },
  {
   "id": "idmt_time-03",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 500 A primary and its TMS is 0.15. How long does it take to operate for a fault current of 8 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.368304,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 8000/500 = 16.0000; t = 0.15 × 0.14 / (16.0000^0.02 − 1) = 0.3683 s"
  },
  {
   "id": "idmt_time-04",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 800 A primary and its TMS is 0.3. How long does it take to operate for a fault current of 8 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.89118,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 8000/800 = 10.0000; t = 0.3 × 0.14 / (10.0000^0.02 − 1) = 0.8912 s"
  },
  {
   "id": "idmt_time-05",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 300 A primary and its TMS is 0.1. How long does it take to operate for a fault current of 2.5 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.323197,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 2500/300 = 8.3333; t = 0.1 × 0.14 / (8.3333^0.02 − 1) = 0.3232 s"
  },
  {
   "id": "idmt_time-06",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 400 A primary and its TMS is 0.1. How long does it take to operate for a fault current of 10 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.210542,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 10000/400 = 25.0000; t = 0.1 × 0.14 / (25.0000^0.02 − 1) = 0.2105 s"
  },
  {
   "id": "idmt_time-07",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 300 A primary and its TMS is 0.4. How long does it take to operate for a fault current of 5 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.967496,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 5000/300 = 16.6667; t = 0.4 × 0.14 / (16.6667^0.02 − 1) = 0.9675 s"
  },
  {
   "id": "idmt_time-08",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 500 A primary and its TMS is 0.15. How long does it take to operate for a fault current of 2.5 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.641958,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 2500/500 = 5.0000; t = 0.15 × 0.14 / (5.0000^0.02 − 1) = 0.6420 s"
  },
  {
   "id": "idmt_time-09",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 600 A primary and its TMS is 0.15. How long does it take to operate for a fault current of 10 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.362811,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 10000/600 = 16.6667; t = 0.15 × 0.14 / (16.6667^0.02 − 1) = 0.3628 s"
  },
  {
   "id": "idmt_time-10",
   "topic": "Overcurrent relay operating time",
   "level": "applied",
   "question": "An overcurrent relay uses the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1), where M is the fault current divided by the pickup current. Its pickup is 300 A primary and its TMS is 0.15. How long does it take to operate for a fault current of 5 kA?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in seconds. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.362811,
   "unit": "s",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "M = 5000/300 = 16.6667; t = 0.15 × 0.14 / (16.6667^0.02 − 1) = 0.3628 s"
  },
  {
   "id": "idmt_grading-01",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 300 A and TMS 0.15. The upstream relay has a pickup of 1000 A. For a 5 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.35 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.166556,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 16.6667, t = 0.15×0.14/(M^0.02−1) = 0.36281 s. Upstream must take 0.71281 s at M = 5.0000: TMS = 0.71281 × (5.0000^0.02 − 1)/0.14 = 0.16656"
  },
  {
   "id": "idmt_grading-02",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 200 A and TMS 0.05. The upstream relay has a pickup of 1000 A. For a 5 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.35 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.106379,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 25.0000, t = 0.05×0.14/(M^0.02−1) = 0.10527 s. Upstream must take 0.45527 s at M = 5.0000: TMS = 0.45527 × (5.0000^0.02 − 1)/0.14 = 0.10638"
  },
  {
   "id": "idmt_grading-03",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 400 A and TMS 0.15. The upstream relay has a pickup of 1200 A. For a 6 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.35 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.169947,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 15.0000, t = 0.15×0.14/(M^0.02−1) = 0.37733 s. Upstream must take 0.72733 s at M = 5.0000: TMS = 0.72733 × (5.0000^0.02 − 1)/0.14 = 0.16995"
  },
  {
   "id": "idmt_grading-04",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 300 A and TMS 0.1. The upstream relay has a pickup of 1200 A. For a 5 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.4 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.132747,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 16.6667, t = 0.1×0.14/(M^0.02−1) = 0.24187 s. Upstream must take 0.64187 s at M = 4.1667: TMS = 0.64187 × (4.1667^0.02 − 1)/0.14 = 0.13275"
  },
  {
   "id": "idmt_grading-05",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 200 A and TMS 0.15. The upstream relay has a pickup of 800 A. For a 4 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.4 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.172933,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 20.0000, t = 0.15×0.14/(M^0.02−1) = 0.34010 s. Upstream must take 0.74010 s at M = 5.0000: TMS = 0.74010 × (5.0000^0.02 − 1)/0.14 = 0.17293"
  },
  {
   "id": "idmt_grading-06",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 400 A and TMS 0.1. The upstream relay has a pickup of 1000 A. For a 5 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.35 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.144918,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 12.5000, t = 0.1×0.14/(M^0.02−1) = 0.27021 s. Upstream must take 0.62021 s at M = 5.0000: TMS = 0.62021 × (5.0000^0.02 − 1)/0.14 = 0.14492"
  },
  {
   "id": "idmt_grading-07",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 400 A and TMS 0.05. The upstream relay has a pickup of 1200 A. For a 10 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.4 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.156335,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 25.0000, t = 0.05×0.14/(M^0.02−1) = 0.10527 s. Upstream must take 0.50527 s at M = 8.3333: TMS = 0.50527 × (8.3333^0.02 − 1)/0.14 = 0.15634"
  },
  {
   "id": "idmt_grading-08",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 400 A and TMS 0.15. The upstream relay has a pickup of 1200 A. For a 8 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.3 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.176812,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 20.0000, t = 0.15×0.14/(M^0.02−1) = 0.34010 s. Upstream must take 0.64010 s at M = 6.6667: TMS = 0.64010 × (6.6667^0.02 − 1)/0.14 = 0.17681"
  },
  {
   "id": "idmt_grading-09",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 300 A and TMS 0.1. The upstream relay has a pickup of 800 A. For a 5 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.3 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.144493,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 16.6667, t = 0.1×0.14/(M^0.02−1) = 0.24187 s. Upstream must take 0.54187 s at M = 6.2500: TMS = 0.54187 × (6.2500^0.02 − 1)/0.14 = 0.14449"
  },
  {
   "id": "idmt_grading-10",
   "topic": "Overcurrent relay grading",
   "level": "analysis",
   "question": "Two overcurrent relays in series both use the IEC standard inverse curve, t = TMS × 0.14 / (M^0.02 − 1). The downstream relay has a pickup of 200 A and TMS 0.1. The upstream relay has a pickup of 1000 A. For a 8 kA fault just beyond the downstream relay, which both relays see, the upstream relay must operate 0.4 s after the downstream relay. What TMS should the upstream relay have?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in a plain number (the TMS). If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 0.176793,
   "unit": "",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Downstream: M = 40.0000, t = 0.1×0.14/(M^0.02−1) = 0.18285 s. Upstream must take 0.58285 s at M = 8.0000: TMS = 0.58285 × (8.0000^0.02 − 1)/0.14 = 0.17679"
  },
  {
   "id": "parallel_unequal-01",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 40 MVA with 12% impedance; T2 is 100 MVA with 10% impedance (each on its own rating). Together they supply 130 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 81.25,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 12/40 = 0.30000, T2 10/100 = 0.10000. T1 carries 130 × 0.10000/(0.30000+0.10000) = 32.5000 MVA = 81.250% of 40 MVA"
  },
  {
   "id": "parallel_unequal-02",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 40 MVA with 10% impedance; T2 is 120 MVA with 16% impedance (each on its own rating). Together they supply 90 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 78.2609,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 10/40 = 0.25000, T2 16/120 = 0.13333. T1 carries 90 × 0.13333/(0.25000+0.13333) = 31.3043 MVA = 78.261% of 40 MVA"
  },
  {
   "id": "parallel_unequal-03",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 80 MVA with 8% impedance; T2 is 120 MVA with 10% impedance (each on its own rating). Together they supply 90 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 51.1364,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 8/80 = 0.10000, T2 10/120 = 0.08333. T1 carries 90 × 0.08333/(0.10000+0.08333) = 40.9091 MVA = 51.136% of 80 MVA"
  },
  {
   "id": "parallel_unequal-04",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 40 MVA with 8% impedance; T2 is 120 MVA with 10% impedance (each on its own rating). Together they supply 70 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 51.4706,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 8/40 = 0.20000, T2 10/120 = 0.08333. T1 carries 70 × 0.08333/(0.20000+0.08333) = 20.5882 MVA = 51.471% of 40 MVA"
  },
  {
   "id": "parallel_unequal-05",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 80 MVA with 8% impedance; T2 is 100 MVA with 14% impedance (each on its own rating). Together they supply 130 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 94.7917,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 8/80 = 0.10000, T2 14/100 = 0.14000. T1 carries 130 × 0.14000/(0.10000+0.14000) = 75.8333 MVA = 94.792% of 80 MVA"
  },
  {
   "id": "parallel_unequal-06",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 80 MVA with 8% impedance; T2 is 60 MVA with 16% impedance (each on its own rating). Together they supply 70 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 63.6364,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 8/80 = 0.10000, T2 16/60 = 0.26667. T1 carries 70 × 0.26667/(0.10000+0.26667) = 50.9091 MVA = 63.636% of 80 MVA"
  },
  {
   "id": "parallel_unequal-07",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 80 MVA with 10% impedance; T2 is 60 MVA with 16% impedance (each on its own rating). Together they supply 90 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 76.5957,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 10/80 = 0.12500, T2 16/60 = 0.26667. T1 carries 90 × 0.26667/(0.12500+0.26667) = 61.2766 MVA = 76.596% of 80 MVA"
  },
  {
   "id": "parallel_unequal-08",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 40 MVA with 8% impedance; T2 is 60 MVA with 10% impedance (each on its own rating). Together they supply 90 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 102.273,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 8/40 = 0.20000, T2 10/60 = 0.16667. T1 carries 90 × 0.16667/(0.20000+0.16667) = 40.9091 MVA = 102.273% of 40 MVA"
  },
  {
   "id": "parallel_unequal-09",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 80 MVA with 10% impedance; T2 is 100 MVA with 12% impedance (each on its own rating). Together they supply 150 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 91.8367,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 10/80 = 0.12500, T2 12/100 = 0.12000. T1 carries 150 × 0.12000/(0.12500+0.12000) = 73.4694 MVA = 91.837% of 80 MVA"
  },
  {
   "id": "parallel_unequal-10",
   "topic": "Unequal transformers in parallel",
   "level": "analysis",
   "question": "Two transformers with the same voltage ratio and the same X/R ratio run in parallel. T1 is 80 MVA with 10% impedance; T2 is 120 MVA with 12% impedance (each on its own rating). Together they supply 90 MVA. What is T1's loading as a percentage of its own rating?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in percent of rating. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 50.0,
   "unit": "%",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "Impedances on a common base are proportional to z/S: T1 10/80 = 0.12500, T2 12/120 = 0.10000. T1 carries 90 × 0.10000/(0.12500+0.10000) = 40.0000 MVA = 50.000% of 80 MVA"
  },
  {
   "id": "resonance-01",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 8 Mvar capacitor bank (rated at 11 kV) is connected at a 11 kV busbar whose three-phase fault level is 400 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 353.553,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(400/8) = 7.0711; f = h × 50 = 353.553 Hz"
  },
  {
   "id": "resonance-02",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 12 Mvar capacitor bank (rated at 11 kV) is connected at a 11 kV busbar whose three-phase fault level is 600 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 353.553,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(600/12) = 7.0711; f = h × 50 = 353.553 Hz"
  },
  {
   "id": "resonance-03",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 5 Mvar capacitor bank (rated at 22 kV) is connected at a 22 kV busbar whose three-phase fault level is 600 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 547.723,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(600/5) = 10.9545; f = h × 50 = 547.723 Hz"
  },
  {
   "id": "resonance-04",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 3 Mvar capacitor bank (rated at 33 kV) is connected at a 33 kV busbar whose three-phase fault level is 150 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 353.553,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(150/3) = 7.0711; f = h × 50 = 353.553 Hz"
  },
  {
   "id": "resonance-05",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 3 Mvar capacitor bank (rated at 11 kV) is connected at a 11 kV busbar whose three-phase fault level is 600 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 707.107,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(600/3) = 14.1421; f = h × 50 = 707.107 Hz"
  },
  {
   "id": "resonance-06",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 8 Mvar capacitor bank (rated at 22 kV) is connected at a 22 kV busbar whose three-phase fault level is 600 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 433.013,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(600/8) = 8.6603; f = h × 50 = 433.013 Hz"
  },
  {
   "id": "resonance-07",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 10 Mvar capacitor bank (rated at 33 kV) is connected at a 33 kV busbar whose three-phase fault level is 150 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 193.649,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(150/10) = 3.8730; f = h × 50 = 193.649 Hz"
  },
  {
   "id": "resonance-08",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 8 Mvar capacitor bank (rated at 33 kV) is connected at a 33 kV busbar whose three-phase fault level is 400 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 353.553,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(400/8) = 7.0711; f = h × 50 = 353.553 Hz"
  },
  {
   "id": "resonance-09",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 5 Mvar capacitor bank (rated at 33 kV) is connected at a 33 kV busbar whose three-phase fault level is 250 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 353.553,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(250/5) = 7.0711; f = h × 50 = 353.553 Hz"
  },
  {
   "id": "resonance-10",
   "topic": "Capacitor bank resonance",
   "level": "applied",
   "question": "A 12 Mvar capacitor bank (rated at 33 kV) is connected at a 33 kV busbar whose three-phase fault level is 600 MVA, on a 50 Hz system. Treating the network as an inductive source behind the fault level, at what frequency does the parallel resonance between the network and the bank occur?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in Hz. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 353.553,
   "unit": "Hz",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "h = √(S_sc/Qc) = √(600/12) = 7.0711; f = h × 50 = 353.553 Hz"
  },
  {
   "id": "fault_with_cable-01",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 1 km 33 kV cable (R = 0.06 Ω/km, X = 0.15 Ω/km per phase) from the 33 kV side of a 60 MVA, 10% transformer with X/R = 40. The transformer's primary busbar has a fault level of 5000 MVA with X/R = 15. Referring everything to 33 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 8.71955,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 33 kV: Zs = 33²/5000 = 0.21780 Ω at X/R 15 → 0.01449+j0.21732; Zt = 0.1×33²/60 = 1.81500 Ω at X/R 40 → 0.04536+j1.81443; Zc = 0.0600+j0.1500; |Z| = 2.18504 Ω; I = 33/(√3×2.18504) = 8.7195 kA"
  },
  {
   "id": "fault_with_cable-02",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 1 km 22 kV cable (R = 0.1 Ω/km, X = 0.1 Ω/km per phase) from the 22 kV side of a 80 MVA, 10% transformer with X/R = 20. The transformer's primary busbar has a fault level of 2000 MVA with X/R = 20. Referring everything to 22 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 13.2782,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 22 kV: Zs = 22²/2000 = 0.24200 Ω at X/R 20 → 0.01208+j0.24170; Zt = 0.1×22²/80 = 0.60500 Ω at X/R 20 → 0.03021+j0.60425; Zc = 0.1000+j0.1000; |Z| = 0.95659 Ω; I = 22/(√3×0.95659) = 13.2782 kA"
  },
  {
   "id": "fault_with_cable-03",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 1 km 33 kV cable (R = 0.06 Ω/km, X = 0.1 Ω/km per phase) from the 33 kV side of a 60 MVA, 14% transformer with X/R = 20. The transformer's primary busbar has a fault level of 2000 MVA with X/R = 20. Referring everything to 33 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 5.97475,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 33 kV: Zs = 33²/2000 = 0.54450 Ω at X/R 20 → 0.02719+j0.54382; Zt = 0.14×33²/60 = 2.54100 Ω at X/R 20 → 0.12689+j2.53783; Zc = 0.0600+j0.1000; |Z| = 3.18884 Ω; I = 33/(√3×3.18884) = 5.9748 kA"
  },
  {
   "id": "fault_with_cable-04",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 2 km 22 kV cable (R = 0.06 Ω/km, X = 0.1 Ω/km per phase) from the 22 kV side of a 60 MVA, 10% transformer with X/R = 20. The transformer's primary busbar has a fault level of 3000 MVA with X/R = 10. Referring everything to 22 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 10.7692,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 22 kV: Zs = 22²/3000 = 0.16133 Ω at X/R 10 → 0.01605+j0.16053; Zt = 0.1×22²/60 = 0.80667 Ω at X/R 20 → 0.04028+j0.80566; Zc = 0.1200+j0.2000; |Z| = 1.17945 Ω; I = 22/(√3×1.17945) = 10.7692 kA"
  },
  {
   "id": "fault_with_cable-05",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 2 km 33 kV cable (R = 0.06 Ω/km, X = 0.12 Ω/km per phase) from the 33 kV side of a 100 MVA, 14% transformer with X/R = 40. The transformer's primary busbar has a fault level of 2000 MVA with X/R = 15. Referring everything to 33 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 8.22796,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 33 kV: Zs = 33²/2000 = 0.54450 Ω at X/R 15 → 0.03622+j0.54329; Zt = 0.14×33²/100 = 1.52460 Ω at X/R 40 → 0.03810+j1.52412; Zc = 0.1200+j0.2400; |Z| = 2.31559 Ω; I = 33/(√3×2.31559) = 8.2280 kA"
  },
  {
   "id": "fault_with_cable-06",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 2 km 22 kV cable (R = 0.06 Ω/km, X = 0.1 Ω/km per phase) from the 22 kV side of a 80 MVA, 14% transformer with X/R = 20. The transformer's primary busbar has a fault level of 5000 MVA with X/R = 20. Referring everything to 22 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 10.9992,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 22 kV: Zs = 22²/5000 = 0.09680 Ω at X/R 20 → 0.00483+j0.09668; Zt = 0.14×22²/80 = 0.84700 Ω at X/R 20 → 0.04230+j0.84594; Zc = 0.1200+j0.2000; |Z| = 1.15478 Ω; I = 22/(√3×1.15478) = 10.9992 kA"
  },
  {
   "id": "fault_with_cable-07",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 5 km 33 kV cable (R = 0.1 Ω/km, X = 0.1 Ω/km per phase) from the 33 kV side of a 60 MVA, 12% transformer with X/R = 40. The transformer's primary busbar has a fault level of 2000 MVA with X/R = 15. Referring everything to 33 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 5.81877,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 33 kV: Zs = 33²/2000 = 0.54450 Ω at X/R 15 → 0.03622+j0.54329; Zt = 0.12×33²/60 = 2.17800 Ω at X/R 40 → 0.05443+j2.17732; Zc = 0.5000+j0.5000; |Z| = 3.27433 Ω; I = 33/(√3×3.27433) = 5.8188 kA"
  },
  {
   "id": "fault_with_cable-08",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 1 km 22 kV cable (R = 0.06 Ω/km, X = 0.12 Ω/km per phase) from the 22 kV side of a 100 MVA, 14% transformer with X/R = 20. The transformer's primary busbar has a fault level of 5000 MVA with X/R = 10. Referring everything to 22 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 14.1279,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 22 kV: Zs = 22²/5000 = 0.09680 Ω at X/R 10 → 0.00963+j0.09632; Zt = 0.14×22²/100 = 0.67760 Ω at X/R 20 → 0.03384+j0.67675; Zc = 0.0600+j0.1200; |Z| = 0.89905 Ω; I = 22/(√3×0.89905) = 14.1279 kA"
  },
  {
   "id": "fault_with_cable-09",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 3 km 22 kV cable (R = 0.06 Ω/km, X = 0.1 Ω/km per phase) from the 22 kV side of a 80 MVA, 10% transformer with X/R = 30. The transformer's primary busbar has a fault level of 3000 MVA with X/R = 15. Referring everything to 22 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 11.6926,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 22 kV: Zs = 22²/3000 = 0.16133 Ω at X/R 15 → 0.01073+j0.16098; Zt = 0.1×22²/80 = 0.60500 Ω at X/R 30 → 0.02016+j0.60466; Zc = 0.1800+j0.3000; |Z| = 1.08631 Ω; I = 22/(√3×1.08631) = 11.6926 kA"
  },
  {
   "id": "fault_with_cable-10",
   "topic": "Fault current through transformer and cable",
   "level": "analysis",
   "question": "A data-centre switchroom is fed by a 3 km 33 kV cable (R = 0.16 Ω/km, X = 0.12 Ω/km per phase) from the 33 kV side of a 60 MVA, 10% transformer with X/R = 30. The transformer's primary busbar has a fault level of 2000 MVA with X/R = 15. Referring everything to 33 kV, with a pre-fault voltage of 1.0 pu and no other sources, what is the three-phase fault current at the switchroom end of the cable?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in kA. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 6.85885,
   "unit": "kA",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "In Ω at 33 kV: Zs = 33²/2000 = 0.54450 Ω at X/R 15 → 0.03622+j0.54329; Zt = 0.1×33²/60 = 1.81500 Ω at X/R 30 → 0.06047+j1.81399; Zc = 0.4800+j0.3600; |Z| = 2.77781 Ω; I = 33/(√3×2.77781) = 6.8588 kA"
  },
  {
   "id": "dc_power_flow-01",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.1 pu), 1–3 (x = 0.2 pu) and 2–3 (x = 0.15 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 150 MW at bus 2 and a data centre draws 500 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 244.444,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[16.667, -6.667], [-6.667, 11.667]]·[θ2, θ3] = [1.5, -5.0] → θ2 = -0.105556, θ3 = -0.488889 rad; P13 = (θ1 − θ3)/x13 = 244.4444 MW"
  },
  {
   "id": "dc_power_flow-02",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.15 pu), 1–3 (x = 0.25 pu) and 2–3 (x = 0.05 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 500 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 138.889,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[26.667, -20.000], [-20.000, 24.000]]·[θ2, θ3] = [2.5, -5.0] → θ2 = -0.166667, θ3 = -0.347222 rad; P13 = (θ1 − θ3)/x13 = 138.8889 MW"
  },
  {
   "id": "dc_power_flow-03",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.15 pu), 1–3 (x = 0.25 pu) and 2–3 (x = 0.05 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 400 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 94.4444,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[26.667, -20.000], [-20.000, 24.000]]·[θ2, θ3] = [2.5, -4.0] → θ2 = -0.083333, θ3 = -0.236111 rad; P13 = (θ1 − θ3)/x13 = 94.4444 MW"
  },
  {
   "id": "dc_power_flow-04",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.1 pu), 1–3 (x = 0.2 pu) and 2–3 (x = 0.15 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 400 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 166.667,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[16.667, -6.667], [-6.667, 11.667]]·[θ2, θ3] = [2.5, -4.0] → θ2 = 0.016667, θ3 = -0.333333 rad; P13 = (θ1 − θ3)/x13 = 166.6667 MW"
  },
  {
   "id": "dc_power_flow-05",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.15 pu), 1–3 (x = 0.2 pu) and 2–3 (x = 0.05 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 400 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 106.25,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[26.667, -20.000], [-20.000, 25.000]]·[θ2, θ3] = [2.5, -4.0] → θ2 = -0.065625, θ3 = -0.212500 rad; P13 = (θ1 − θ3)/x13 = 106.2500 MW"
  },
  {
   "id": "dc_power_flow-06",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.2 pu), 1–3 (x = 0.1 pu) and 2–3 (x = 0.15 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 300 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 122.222,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[11.667, -6.667], [-6.667, 16.667]]·[θ2, θ3] = [2.5, -3.0] → θ2 = 0.144444, θ3 = -0.122222 rad; P13 = (θ1 − θ3)/x13 = 122.2222 MW"
  },
  {
   "id": "dc_power_flow-07",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.15 pu), 1–3 (x = 0.2 pu) and 2–3 (x = 0.1 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 500 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 194.444,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[16.667, -10.000], [-10.000, 15.000]]·[θ2, θ3] = [2.5, -5.0] → θ2 = -0.083333, θ3 = -0.388889 rad; P13 = (θ1 − θ3)/x13 = 194.4444 MW"
  },
  {
   "id": "dc_power_flow-08",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.15 pu), 1–3 (x = 0.1 pu) and 2–3 (x = 0.1 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 250 MW at bus 2 and a data centre draws 300 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 107.143,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[16.667, -10.000], [-10.000, 20.000]]·[θ2, θ3] = [2.5, -3.0] → θ2 = 0.085714, θ3 = -0.107143 rad; P13 = (θ1 − θ3)/x13 = 107.1429 MW"
  },
  {
   "id": "dc_power_flow-09",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.2 pu), 1–3 (x = 0.2 pu) and 2–3 (x = 0.1 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 150 MW at bus 2 and a data centre draws 400 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 180.0,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[15.000, -10.000], [-10.000, 15.000]]·[θ2, θ3] = [1.5, -4.0] → θ2 = -0.140000, θ3 = -0.360000 rad; P13 = (θ1 − θ3)/x13 = 180.0000 MW"
  },
  {
   "id": "dc_power_flow-10",
   "topic": "Three-bus DC power flow",
   "level": "analysis",
   "question": "A three-bus network has lines 1–2 (x = 0.1 pu), 1–3 (x = 0.25 pu) and 2–3 (x = 0.05 pu) on a 100 MVA base; resistance and losses are neglected. Bus 1 is the slack bus. A generator injects 200 MW at bus 2 and a data centre draws 500 MW at bus 3. Using a DC power flow, how much real power flows on line 1–3, from bus 1 towards bus 3?\n\nShow your working if you like, then end with one line in the form `ANSWER: <number>` giving only the number, in MW. If the question cannot be answered from the information given (a value it needs is missing, or the data contradict each other), end instead with `ANSWER: insufficient`.",
   "answer": 137.5,
   "unit": "MW",
   "tolerance": {
    "relative": 0.01
   },
   "solution": "B'θ = P with θ1 = 0: [[30.000, -20.000], [-20.000, 24.000]]·[θ2, θ3] = [2.0, -5.0] → θ2 = -0.162500, θ3 = -0.343750 rad; P13 = (θ1 − θ3)/x13 = 137.5000 MW"
  }
 ]
}